Description
The Teledyne GaN PowerMAX Indoor Modular N+1 Phase Combined SSPA System maintains complete parallel redundancy down to the embedded control level. Therefore the loss of an entire HPA chassis will not interrupt remote communications with the system. Remote communications can be either RS-485 or Ethernet. The Teledyne GaN PowerMAX Indoor Modular N+1 Phase Combined SSPA System will automatically correct its gain level in the event of one or more HPA chassis failures.
The Teledyne GaN PowerMAX Indoor Modular N+1 Phase Combined SSPA System’s sophisticated monitor and control allows the system to be locally or remotely operated as if it were a “single” chassis amplifier. The system control maintains a hierarchical management that allows the operator to interface to a single chassis of the multi-module array.
Another feature unique to Teledyne Paradise Datacom’s PowerMAX is the introduction of “true rms” output power measurement. Unlike other amplifier systems that utilize diode detection schemes, the PowerMAX reports the true rms output power of the system independent of the number of carriers and modulation schemes. Proprietary waveguide combining techniques are employed so that maximum power combining efficiency is optimized within the operating frequency band.
Teledyne GaN PowerMAX Indoor Modular N+1 Phase Combined SSPA System Features
- Gallium Nitride amplifiers, offering better power over frequency
- Output Power levels of up to:
10 kW in S-Band;
11 kW in C-Band;
10 kW in X-Band;
7 kW in Ku-Band;
1.8 kW in Ka-Band - No Active Switching-All Passive Power Combining
- System is 100% field maintainable for low MTTR
- Output Power sized for N+1 Redundancy
- All active modules are hot swappable via the front or rear panels
- Hot Swappable Redundant Power Supply Modules
- Hot Swappable SSPA Modules
- Color Touchscreen Display
- Removable Fan Trays
- Removable M&C Card Assembly
- System monitor and control emulates single SSPA Chassis operation
- Ethernet Port with UDP, SNMP, and internal web browser capability
- Legacy RS-485 M&C
- True Output Power Measurement
- Reflected Power Monitor
- RF Output Sample Port
- System is field scalable: i.e., can start out with (4) modules in system and upgrade to (8) or (16) modules.
- Optional Waveguide Arc Protection Kit
SSPA Chassis Population Options
The PowerMAX system is available in a variety of system GaN module configurations and output power levels. The system is based on Teledyne Paradise Datacom’s 3RU chassis with 100% hot swappable active assemblies. The units can be configured with a wide variety of SSPA frequency bands and power levels, and can be fitted with the following SSPA modules:
- S-Band: 300W, 400W, 500W, 600W, 800W, 1 kW
- C-Band: 150W, 200W, 300W, 400W, 500W, 650W, 800W, 1 kW
- X-Band: 300W, 400W, 650W, 800W
- Ku-Band: 150W, 200W, 300W,
System Output Power and Configurations
Because the system power combining is purely passive and no switching is used, there is never an interruption in RF output power. The PowerMAX system is typically used as a “self-redundant” system. The output power is sized such that the loss of (1) RF module’s power will still allow the system to maintain its minimum required output power. This type of system architecture is described as n+1 redundant. The system can be configured with any number of modules but best overall efficiency is obtained with the popular binary combinations of 4, 8, or 16 modules. It is very easy to upgrade the PowerMAX system from 4 modules to 8 or 16 modules in the field. It is not necessary to fully populate the system at the time of initial purchase. This provides the user a path to upgrade output power capability as system requirements grow, thus keeping capital investment minimized.
For sizing redundant output power capability use the following guideline to determine the output power of the system with the loss of (1) module.
- 4 Module System – 3 of 4 Modules Operable = 2.5 dB loss in output power capability
- 8 Module System – 7 of 8 Modules Operable = 1.2 dB loss in output power capability
- 16 Module System – 15 of 16 Modules Operable = 0.6 dB loss in output power capability
Hitless Redundancy
For mission critical systems in which no power outage can be tolerated, an eight module PowerMAX system can be operated with only four modules installed. In this way, the additional four modules can be installed without requiring the system to be powered off.
The only disadvantage of operating the eight module PowerMAX system with four modules is the additional 3 dB loss that the four module (half-system) system experiences by going through the final hybrid combiner as shown at right. Therefore the overall output power is
actually 6 dB below what it would be with all eight modules present in the system.
If, however, the module output power is sized such that this reduction in output power can be tolerated, the system is an effective means of scaling the system from four to eight modules and maintaining true hitless operation. The system never has to be powered down and there are no mechanical switches involved that would create an interruption of service.
With parallel system architectures, the amplifier output power capability and gain will change as the number of active modules vary. The PowerMAX system is designed with an Auto-Gain Control mode so that the overall system gain will remain constant in the event of a single module failure. Refer to Technical Data Sheets for detailed 4, 8 and 16 SSPA Module configurations.
Teledyne Paradise Datacom develops innovative satellite modems, solid state power amplifiers (SSPA), low noise amplifiers (LNA), block up converters (BUC) and related subsystems for leading SATCOM organizations worldwide in the military and commercial markets. Teledyne Paradise Datacom is a part of Teledyne Microwave Solutions. Highly competitive pricing is achieved by enabling only the features you need at any time. Future-proofing is assured by convenient software upgrades via Ethernet or a memory stick and lots of processing headroom, protecting your investment.